| Model LA2305
Scanning Fluorescence Detector |
|
|
Buy This Detector For: |
| |
- High Sensitivity
- Really long lamp life (5600 hours and maximum flash rate)
- Very Easy to Use
- Compatible with any HPLC system with an analogue input
|
| |
| |
|
|
| Features & Benefits |
|
Specification |
- High-efficiency holographic diffraction gratings are optimised for high sensitivity at both lower and higher excitation wavelengths.
|
|
H x W x D |
170mm x 300mm x 400mm |
| Weight |
11.0 kg (approx) |
| Power |
240V, 50Hz, 2Amps max |
- Choice of three spectral bandwiths
|
|
Display |
2 x 24 characters |
- Pulsed xenon lamps provides a high energy level across the entire UV/Vis spectrum without generating ozone.
|
|
|
|
Optical Design - Dual Monochromators using concave holographic, stepper motor driven diffraction gratings.
Sensitivity - S/N>1500 for 2µg/L anthracene in MeOH; 248nm Ex/ 398nm Em
Wavelegth Range - 200 - 650nm excitation and emission
200 - 800nm emission with optional extended range PMT Wavelength Accuracy - ±2nm @ 248nm Ex / 398nm Em
Wavelength Precision - <0.5nm
Spectral Bandwidth - 8, 20 or 30nm selectable
Lamp - Pulsed Xenon, selectable 20 or 100Hz
Flow Cell - High-purity quartz, Teflon®, Kalrez®, and PEEK; 8 µL illuminated volume; maximum pressure: 200 psi (14 bar).
Spectral Scanning - Automatic or manual; 100 steps per second; step size selectable; 2, 4, 8, 16, or 32 nm; up to 60 spectra stored in memory.
Range Selections - 500, 200, 100, 50, 20, 10, 5, 2, 1, 0.5, 0.2, 0.1, 0.05, 0.02, 0.01 FUFS
Operating Modes - Fluorescence; phosphorescence; chemiluminescence.
Analog Outputs - 2, Range-selectable over entire fluorescence range using 20-bit D/A
Fluorescence range - 0.01-500 fluorescence units full scale
Method files - 4 user files protected in memory; files can
be linked via queue; 10 time lines per file for wavelength changes; automatic zero
Ambient environment - 10-40° C, 5-95% relative humidity, noncondensing
Communication - Remote inputs:Run, Stop, Zero
Output:Ready |
- Fluctuations in lamp intensity are automatically maintained and corrected to reduce noise and drift.
|
|
- 20-bit digital electronics greatly enhance quantitative accuracy and precision over a wide dynamic range.
|
|
- Time programming of the Ex wavelength and Em wavelength lets you optimise sensitivity and selectivity
|
|
- Automatic real time scanning of eluting peaks helps you identify optimum wavelengths.
|
|
- Sixty stored spectra can be displayed on the LCD or via an external data system
|
|
- Lamp and flow cell are at the front of the detector and come pre aligned for ease of maintenance.
|
|
- Biocompatible flow cell available
|
|
- Pulsed Xenon lamp. This means no warm up time, the lamp only needs to flash during the run, and a lamp life of 5600 hours on max flash rate, compared to maybe 500 hours for a standard Xenon lamp.
|
|
| |
|
| |
|
| |
|
| |
|
| Ordering Information |
| Scanning Fluorescence Detector |
LA2305/00 |
|
|
|
|
|